RCD 40A 2P 6kA 30mA RCCB R9R06240
PDL Resi9 R9R06240 40A RCCB/RCD – Reliable 2P Type A residual current protection with 30mA sensitivity, 400V AC operation and DIN-rail mounting for residential switchboards.
$47.64
Guaranteed Safe Checkout
Features & Compatibility
PDL Resi9 40A 2P RCCB 30mA Type A – R9R06240
The PDL Resi9 R9R06240 Residual Current Circuit Breaker (RCCB) is designed to provide residual current protection for electrical installations. This 2-pole, 40A RCCB features Type A protection and 30mA earth-leakage sensitivity, making it suitable for residential and distribution board applications where additional protection against residual current faults is required. The device is rated to AS/NZS 61008.1.
The R9R06240 has a 400V rated operational voltage and uses an instantaneous residual-current protection response. Its 2-pole configuration allows the connected circuit to be switched and isolated through the device, while the clear ON/OFF indication makes the operating status easy to identify.
Designed for modular switchboards, the RCCB clips directly onto a DIN rail and has a compact 36mm width. The device features tunnel-type terminals and is suitable for use with compatible Resi9 MCBs. PDL specifies a 500A rated breaking and making capacity and a 6kA conditional short-circuit current when used with the specified Resi9 MCB.
Key Features
- PDL Resi9 RCCB
- 2-pole configuration
- 40A rated current
- Type A residual current protection
- 30mA earth-leakage sensitivity
- 400V AC rated voltage
- Instantaneous residual-current protection
- DIN-rail mounting
- Clear ON/OFF indication
- RCM quality label
- Suitable for residential and distribution boards
Product Specifications
| Specification | Details |
|---|---|
| Brand | PDL / Schneider Electric |
| Range | Resi9 |
| Product Code | R9R06240 |
| Product Type | RCCB |
| Poles | 2P |
| Rated Current | 40A |
| Rated Voltage | 400V AC |
| RCD Type | Type A |
| Residual Current | 30mA |
| Response | Instantaneous |
| Standard | AS/NZS 61008.1 |
| Additional Standards | IEC 61008-2-1, EN/IEC 61008-1 |
| Width | 36mm |
| Height | 85mm |
| Depth | 75mm |
| Mounting | DIN Rail |
| IP Rating | IP20 |
| Rated Breaking & Making Capacity | 500A |
| Conditional Short-Circuit Current | 6kA |
| Certification | RCM |
The R9R06240 has a rated insulation voltage of 440V AC, a 4kV impulse withstand voltage, and mechanical endurance of up to 10,000 cycles, with electrical endurance of up to 4,000 cycles
Additional information
| Weight | .2 kg |
|---|